Logic
Definition
Serial mode
(Identifies how board
SERIAL
ODE
is configured in a BFT
network connection).
Address
ADDRESS
Push&Go
(Only for
PUSH go
E5 BT A12)
Configuration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
1-2
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Configuration of
EXPO1
output
on input-output
EXPO1
expansion board
4-5
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
TRAFFIC LIGHT
Traffic light pre-
flashing
PREFLASHING
TRAFFIC LIGHT
Steadily lit red light
RED LA P
ALWAYS ON
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
0
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
Identifies board address from 0 to 119 in a local BFT network connection.
0
[ ___ ]
(see U-LINK OPTIONAL MODULES section)
0
Logic not active
0
1
Manually pushing the stopped leaf toward the opening direction determines the automatic opening.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
11
the movement stops.
1
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
12
the movement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is
13
switched automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
14
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/
15
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is
16
switched automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing
17
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening
18
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
0
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
11
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
12
the movement stops.
0
Output configured as 2
1
Output configured as SCA (gate open light).
11
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
11
8
Output configured as Magnetic lock.
9
Output configured as Traffic Light control with TLB board.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
0
Pre-flashing switched off.
0
1
Red lights flash, for 3 seconds, at start of operation.
0
Red lights off when gate closed.
0
1
Red lights on when gate closed.