TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
OPEN DELAY
0
10
TI E
CLS DELAY
0
25
TI E
0
120
TCA
TRF. L GHT.
1
180
CLR. T
OP. D IST.
0
50
SLOUD
CL. D IST.
0
50
SLOUD
0
50
DIST. D ECEL
PARTIAL
10
99
OPENING
1
99
OP. F ORCE
1
99
CLS. F ORCE
15
99
OP SPEED
15
99
CL SPEED
SLOW SPEED
15
99
ainte-
0
250
nance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
34 -
THALIA
INSTALLATION MANUAL
Default
Personal
Definition
Motor 2 opening delay
3
time [s]
Motor 1 closing delay
6
time [s]
10
Automatic closing time [s]
Time-to-clear traffic light
40
zone [s]
Slow-down distance during
10
opening [%]
Slow-down distance during
10
closing [%]
15
Deceleration distance [%]
99
Partial opening M1 [%]
Leaf force during
50
opening [%]
Leaf force during
50
closing [%]
99
Opening speed [%}
99
Closing speed [%]
25
Slow-down speed [%]
Programming number of
operations for maintenance
0
threshold
[in hundreds]
Description
Motor 2 opening delay time with respect to motor 1.
Motor 1 closing delay time with respect to motor 2.
NOTE: if the time is set to maximum, before starting, engine 1 waits for the complete
shut down of engine 2.
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
Slow-down distance for motor(s) during opening, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-
closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active slowdown
to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded; values
below 10% will be considered to be 10%.
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-
closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active slowdown
to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded; values
below 10% will be considered to be 10%.
Deceleration distance (switch from running speed to slow-down speed) for motor(s) both
during opening and during closing, given as a percentage of total travel. WARNING: Once the
parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation of PED
pedestrian command.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered,
beyond the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices
where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force delivered,
beyond the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices
where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET", obstacle
detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing. WARNING:
Once the parameter has been edited, a complete uninterrupted opening-closing cycle
is required. WARNING: when the display reads "SET", obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a percentage of
maximum running speed. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: When the display reads
""SET"", obstacle detection is not active.
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded; values
below 50% will be considered to be 50%.
Allows you to set a number of operations after which the need for maintenance will
be reported on the AUX output configured as Maintenance or Flashing Light and
Maintenance .