Electrical Pluging And Adjusting The Disk Direction Of Rotation; Electrical Scheme - Carat EASYCOUPNEXT 350 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
4 ELECTRICAL PLUGING AND ADJUSTING THE DISK DIRECTION OF
ROTATION.
Upon receipt of the machine, make sure the network electrical tension is adequate before plugging the machine. The
electrical tension is to be found on the voltage indication next to the
switch of the machine.
WARNING: Never plug the machine to the main supply
without making sure that the power tension is compatible
with the machine specifications. Otherwise the motor
would suffer irreparable damages.
Once you have gone through the previous steps it is necessary to check and adjust the rotation of the motor axis
correctly: you have to plug the machine to the main supply and start it up, making sure that the blade rotates
clockwise.
If necessary, you can change the rotation direction swapping the two phase wires in the aerial or in the peg of the
feeding extension cord. Please do it with the machine unplugged.
WARNING: Never manipulate power supply cables or any other electrical
equipment on the machine before making sure that the machine is totally
unplugged from the electricity supply.
WARNING: Unplug the machine from the network before proceeding to
change the position of the bridge plates on the engines. You should also
proceed to change the stickers indicating the supply voltage, so there will
always be indicated on the machine rated voltage.

5 ELECTRICAL SCHEME.

The electrical equipment of the table saws has an IP54 protection degree.
The switch of this machine is equipped with an under voltage trip device to prevent an unwanted start of the machine.
In case of a supply cut or a voltage drop causing the machine to stop, once the power supply has been restored the
machine will not get started again until the start green button is pushed.
WARNING: The three phase cutters are prepared to
operate at 400 V by default.
WARNING: Should it be necessary to use a three phase
power input of 230 V, please, connect the bridge plates in the
motor terminal box as in the picture below.
WARNING: when using an extension cable to feed the machine, this cable should have a minimum section
as in the table below.
MOTOR
CONEXIÓN
1 Phase/ Mono. 110V 50/60Hz
2,2 Kw
1 Phase/ Mono. 230V 50/60Hz
3 kw
3 Phase/ Trif. 230V 50/60Hz
3 Phase/ Trif. 400V 50/60Hz
0 - 10 m
10 - 20 m
2,5 mm2
6 mm2
2,5 mm2
2,5 mm2
2,5 mm2
2,5 mm2
2,5 mm2
2,5 mm2
6
20 - 30 m
10 mm2
4 mm2
4 mm2
2,5 mm2