RODEO
SERIE
CONNECTION FOR ELECTRIC LOCK
MA7012
CONNECTION FOR
OPERATING SYSTEM
10
11
.1 .2 ES ES
TX RX GN D
1
2
MA7012
BUSSOLA
C1
Ri
M.9011 - M.9111
M
R2
+
R1
2
P.R.AP
AP/PARZ
TCA
SEAT FOR PHOTOCELL CARD
9011-9111
MF
TERMINAL BOARD FOR CONNECTION
OF ACCESSORIES
24V
230V
10
+
11
.1 .2 ES ES
1
2
MA7012
C1
Ri
M
R2
+
R1
2
P.R.AP
- Contact 1-2 and 2-C1 are normally closed (N.C.) and bridged together at the factory. To use these functions, replace
the bridge connections with the relative devices.
- The 2-C1 contact is used when a security system is desired (for example, photoelectric cells or other control
devices), which is not capable of being housed in the special clip-in seat. Note: if the MA9011/9111 photoelectric cell
card is not enabled, or if it is enabled and you wish to disable it, set dip switch 3 to ON (4-way module).
- The 2-M contact is normally open (N.O.), and has a double function:
1) During normal functioning it is enabled for opening, even if the MA7041 function selector is set on "doors closed".
This function can be used for preferential passage, (e.g., evening closure, opening command on key or magnetic
switches).
2) By setting dip switch 5 to ON (10-way module), the "stepper" opening function is enabled (by pressing the button
the door opens; pressing it again closes the door). Attention, by using this function contacts 2-R1 and 2-R2 are
excluded.
14
ZP8
ELECTRICAL
CONNECTION FOR FUNCTION SWITCH
"
"
COMPASS
-
RAPID
BLOW
ACCESSORIES
.USIBILE
1 2 3 4
5 6 7
ACCESSORI
1,6A
MA7041
V.RALL.CH
V/CH
V/AP
P.R.CH
.RENO
V.RALL.AP.
ADJUSTMENT TRIMMERS
POWER SUPPLY CONNECTION TERMINAL BOARD
24V
230V Power supply (50/60 Hz)
(see page 22)
TERMINAL BOARD FOR CONNECTION OF ACCESSORIES
10 - 11 24V a.c./d.c. power to accessories
1 - 2
Pushbutton Stop, normally close contact (N.C.)
2 - C1 Photocells, re-opening during closing (N.C.)
2 - Ri Normally open contact (N.O.) for central sensor (used only
when interface system is installed)
2 - R1 Normally open contact (N.O.) external sensor (can be excluded)
2 - R2 Normally open contact (N.O.) internal sensor
2 - M
Normally open contact (N.O.), for "step-by-step" operation
(manual button)
CABINET
MA7041
INDICATOR LEDS
1.6A
FUSE ON
1 2 3 4 5 6 7 8
RESET
MA7032
O
1
2
3
4
5 6
7 8
9 10
O
1
2
3
4
APRE
N
N
-
DIP
SWITCHES
SEAT FOR EMERGENCY OPERATION CARD
Reduction gear power supply (supplied standard)
Earth connection
Line fuse 2A
TERMINAL BOARD FOR CONNECTION OF
-
MOTOR
ENCODER
SUPPLY
RESET KEY
OPEN KEY
7032
MA
-
-
BATTERY
POWER
24V
M
N
E
+
S
S
E
-
-
BATT.
+
24AC
24AC