WEG CF W501 V1.8X Referencia Rápida página 16

Idiomas disponibles

Idiomas disponibles

Quick Parameter Reference, Faults and Alarms
Param.
Function
P0320 FlyStart/Ride-Through
P0331 Voltage Ramp
P0340 Auto-Reset Time
P0343 Mask for Faults and
Alarms
P0349 Ixt Alarm Level
P0397 Control Config
P0398 Motor Service Factor
P0399 Motor Rated Eff.
P0400 Motor Rated Voltage
P0401 Motor Rated Current
P0402 Motor Rated Speed
P0403 Motor Rated Frequency
P0404 Motor Rated Power
14 | CFW501
Adjustable Range
0 = Inactive
1 = Flying Start
2 = FS / RT
3 = Ride-Through
0.2 to 60.0 s
0 to 255 s
0000 to FFFFh
Bit 0 = F0074
Bit 1 = F0048
Bit 2...3 = Reserved
Bit 4 = F0076
Bit 5....15 = Reserved
70 to 100 %
0000 to FFFFh
Bit 0 = Slip Compens. Regen.
Bit 1 = Dead Time Compens.
Bit 2 = Io Stabilization
Bit 3 = P0297 Reduction
Temperature
1.00 to 1.50
50.0 to 99.9 %
200 to 600 V
0 to 200.0 A
0 to 30000 rpm
0 to 500 Hz
0 = 0.16 hp 0.12 kW
1 = 0.25 hp 0.19 kW
2 = 0.33 hp 0.25 kW
3 = 0.5 hp 0.37 kW
4 = 0.75 hp 0.55 kW
5 = 1 hp 0.75 kW
6 = 1.5 hp 1.1 kW
7 = 2 hp 1.5 kW
8 = 3 hp 2.2 kW
9 = 4 hp 3 kW
10 = 5 hp 3.7 kW
11 = 5.5 hp 4 kW
12 = 6 hp 4.5 kW
13 = 7.5 hp 5.5 kW
14 = 10 hp 7.5 kW
15 = 12.5 hp 9 kW
16 = 15 hp 11 kW
17 = 20 hp 15 kW
18 = 25 hp 18.5 kW
19 = 30 hp 22 kW
Factory
User
Propr. Groups Pag.
Setting
Setting
0
2.0 s
0 s
0003h
85 %
000Bh
1.0
75.0 %
220(230) V
(P0296 = 0)
380(400) V
(P0296 = 1)
575(525) V
(P0296 = 2)
1.0xI
nom
1710 (1425) rpm
60 (50) Hz
According to
inverter model
cfg
11-9
11-9
14-11
cfg
14-4
cfg
14-3
cfg
8-2
cfg
MOTOR,
10-4
STARTUP
cfg,
MOTOR,
10-5
V V W
STARTUP
cfg
MOTOR,
10-5
STARTUP
cfg
MOTOR,
10-6
STARTUP
cfg
MOTOR,
10-6
STARTUP
cfg
MOTOR,
10-6
STARTUP
cfg
MOTOR,
10-6
STARTUP
loading