REV.0-10/10
Technical Data
GENERATOR
*Stand-by three-phase power
*PRP three-phase power
*Stand-by single-phase power
*PRP single-phase power
Frequecy
Cos ϕ
* Output powers according to ISO 8528-1
ALTERNATOR
Type
Insulation class
MOTOR
Make / Model
Type / Cooling system
Cylinder / Displacement
*Stand-by net power
*PRP net power
Speed
Fuel consumption (75% of PRP)
Engine oil capacity
Starter
* Output powers according to ISO 3046-1
GENERAL SPECIFICATION
Fuel tank capacity
Running time (75% of PRP)
Protection
*Dimensions on base Lxwxh
*Weight on base
Acoustic power LwA (pressure LpA)
* Dimensions and weight without trolley/trailer.
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the PRP.
It's admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
(L
Acoustic Noise Level
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(L
)
of 95 dB(A)
WA
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
PLEASE NOTE: the symbol
according to 2000/14/CE directive.
Technical data and machine description
GE 10000 LD/GS
-
-
10 kVA (9 kW) / 230 V / 43.5 A
9 kVA (8.1 kW) / 230 V / 39.1 A
50 Hz
0.9
Self-excited, self-regulated, brushless
synchronous, single-phase
H
159 Kg
99 dB(A) (74 dB(A) @ 7 m)
ACOUSTIC POWER LEVEL
)
- Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
WA
when with acoustic noise values, indicates that the device respects noise emission limits
2000 / 14 / CE
Lombardini / 25 LD 425/2
Diesel 4-Stroke / air
2 / 851 cm
3
11.5 kW (15.6 HP)
10.5 kW (14.3 HP)
3000 rpm
2.2 l/h
1.8 l
Electric
18 l
8.2 h
IP 23
935x580x645
OUTPUT
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
1
GE
0000 LD/GS
1
GE
2000 LD/GS
GE 12000 LD/GS
12 kVA (9.6 kW) / 400 V / 17.3 A
11 kVA (8.8 kW) / 400 V / 15.9 A
-
6 kVA / 230 V / 26 A
50 Hz
0.8
Self-excited, self-regulated
synchronous, three-phase
H
156 Kg
99 dB(A) (74 dB(A) @ 7 m)
M
1.5