nord NORDAC PRO SK 500P Manual De Instrucciones página 151

Tabla de contenido
Pos : 435 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/P480 - Funkt. Bus IO in Bits [SK 500P] @ 25\mod_1543845850671_2870.docx @ 2467339 @ @ 1
P480
Rango de
configuración
Arrays
Configuración de
fábrica
Descripción
Nota
Pos : 436 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265512 @ @ 1
BU 0600 es-1020
Func.BusIO In Bits
0... 82
[-01] =
Bus / 2ªAES Dig In1
[-02] =
Bus / 2ªAES Dig In2
[-03] =
Bus / 2ªAES Dig In3
[-04] =
Bus / 2ªAES Dig In4
[-05] =
Bus / 1ªAES Dig In1
[-06] =
Bus / 1ªAES Dig In2
[-07] =
Bus / 1ªAES Dig In3
[-08] =
Bus / 1ªAES Dig In4
[-09] =
Memoria 1
[-10] =
Memoria 2
[-11] =
Bit 8 Bus palabra de
control
[-12] =
Bit 9 Bus palabra de
control
[-01] = { 1 }
[-02] = { 2 }
«Función Bus IO In Bits". Los Bus IO In Bits se consideran entradas digitales P420.
Pueden configurarse para las mismas funciones.
Para poder usar esta función debe ajustarse una de las consignas de bus P546 en la
configuración «BusIO In Bits 0-7». Después debe asignarse la función deseada al bit
correspondiente.
Encontrará las funciones posibles para los Bus In Bits en la tabla de las funciones de
las entradas digitales. La función 14 "Telemando" no es posible.
In Bit 0 ... 3 a través de bus o
de entrada analógica 1... 4 de la 2.ª ampliación de
entradas/salidas
In Bit 4 ... 7 a través de bus o
de entrada analógica 1... 4 de la 1.ª ampliación de
entradas/salidas
Véase «Uso de las marcas» después de la
descripción de los parámetros P481
Asignación de una función para el bit 8 o 9 de la
palabra de control
[-03] = { 4 }
[-04] = { 5 }
5 Parámetro
S
el resto { 0 }
151
Tabla de contenido
loading

Este manual también es adecuado para:

Nordac pro sk 510pNordac pro sk 530pNordac pro sk 550p

Tabla de contenido