Dometic TEC 30D EV Manual De Instrucciones Para El Uso, Mantenimiento E Instalación página 35

Ocultar thumbs Ver también para TEC 30D EV:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 252
As an example, the illustration shows the minimum and maximum temperatures of use
for the various lubricant grades.
If a "MONOGRADE" type lubricant is used (for example 10W, 30, etc.), choose the
grade based on the average ambient temperature in which the equipment is used.
CHECK OIL LEVEL
Important
Check the oil level when the equipment is perfectly level.
Proceed as indicated.
1 -Turn the unit on and allow it to
warm up for a few minutes.
2 -Turn the unit off.
3 -Wait for a few minutes to allow all
the oil to flow into the sump.
4 -Open the door (A).
5 -Extract the dipstick (B) and check
the oil level; top up if necessary. For
the amounts of oil, see "Technical
data".
- 35 -
Use, maintenance and installation instructions
TEC 30D EV
GB
40200702700.tif
(A)
Door
(B)
Level rod
40200800500.tif
Tabla de contenido