Hard Wire Installation - Dimplex Revillusion RBF24DLX El Manual Del Propietario

Ocultar thumbs Ver también para Revillusion RBF24DLX:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Electrical

Hard Wire Installation

WARNING: Make sure the circuit
on which the fireplace is to be installed
has the power cut off at the service
panel until installation is complete.
1.
Allow 8" (20.3 cm) of service cable
for connecting power supply wire
to junction box on the unit when
installing and before finishing the
wall. Allow up to 4 ft (122 cm) of
service cable for connecting power
supply wire to junction box when
installing after finishing wall.
2
. Wire a dedicated, properly fused
circuit with a 15 A rating.
3
. Feed the service cable through
the electrical cover on the back of
the unit and secure using a 1/2"
(1.3 cm) approved strain relief
connector.
4
. Remove the outer jacket and strip
the individual conductors 1/2"
(1.3 cm) from the end.
5.
Follow the following instructions for
your specific installation.
6
. Wiring inspection can be done from
the front of the unit: remove the
access panel, to the right of the
controls, to access the service cable
and wires from the unit.
12
Direct Power Wiring (120 V)
All wiring must be completed prior to
installing the electric fireplace.
Use 2-conductor wires with ground
(3 wires total) from the power supply
(breaker panel) to the junction box on
the electric fireplace.
To install 120 V direct power wiring:
1.
2.
3.
4.
5
. Insert all the wiring back into the
6
. Make sure all connections are tight.
RED - N
BLACK
GROUND - G
Pull out the RED-N, BLACK, and
GROUND-G wires.
Connect N (white) and N (red) in the
fireplace to the N (white) from the
power supply.
Connect L (black) wire from the
fireplace to the L1 (black) from the
power supply.
Connect the G (green) ground wire
from the fireplace to the ground from
the power supply.
fireplace and secure with a cable
clamp.
WHITE - N
BLACK - L1
GROUND - G
120 V
POWER
SUPPLY
BREAKER
PANEL
www.dimplex.com
Tabla de contenido
loading

Este manual también es adecuado para:

Revillusion rbf24dlxwc

Tabla de contenido