Power connection of the equipment
Before accessing the connecting terminals, verify that the cables are
not under electric voltage. The opening of the envelope does not
imply the absence of tension within it. It may only be opened by
authorized and qualified personnel.
Once mounted on the wall, perform electrical connections according to the
following connection scheme:
SINGLE PHASE
230 V~
N
L
Max. 32A
Max. 16A
OPCIONAL
OPTIONAL
The terminals marked as Optional are to connect the supply of the additional
Schuko output. This connection should be protected with independent
protections.
If your VIARIS UNI does not have as option the additional Schuko output these
terminals are not functional, avoid making a connection in them.
In the event that your charger has the extra MID meter, the electrical supply
connections will be made on the meter itself, respecting the order of the phases
indicated on the device.
230 V~
N
L
THREE-PHASE
3x230/400 V~
N
L3
L2 L1
Max. 3x32A
71
ENG
230 V~
N
L
Max. 16A
OPCIONAL
OPTIONAL