PROCEDURE 4 - Memorising (in the receiver) the control unit Series/Address, for the BusT4
network
01.
Disconnect the power supply and wait 5 seconds.
02.
Hold down key A of the receiver and simultaneously restore the
power supply:
LED B emits some initial flashes (Chapter 3); it will then emit 2
short orange flashes; lastly, when the steady green light appears
(*3), release key A.
(*3) Note - If the LED emits a steady red light, it means that the memorisation procedure was not com-
pleted. In this case, repeat the procedure from the beginning.
WARNING! - Once the Series/Address has been memorised, the receiver will drive the control unit only through
BusT4. The Stand-By function cannot be active on the control unit. To enable the Stand-By function on the control
unit, do not run the "Memorising the control unit Series/Address for the BusT4 network" procedure.
9 - English
OFF
5
s
ON
+
...