OUTPUTS 100MDC SERIES
DETERMINING OUTPUT FOR DUAL HEAD DUAL CONTROL MODEL
• The dial ring is labeled L-10; L = 5%, 1-10 indicates approximately 10% of maximum output.
• Setting #10 on both feed rate controls will deliver the pump's maximum output.
• The innermost head is the primary output. The outermost head operates at a percentage
of the innermost head.
• Example Using 100MCD5
Select the output from the chart for the innermost head, and then calculate the outermost
head output.
Innermost Head Output x Setting % of Outermost Head = Outermost Head Output
Example: The output of the innermost head at setting #4 = 20 gpd. The output of the
outermost head at setting #3 is 30%; and would be calculated 20 gpd x 30% = 6 gpd.
APPROXIMATE GPD @ 60Hz – INNERMOST HEAD OUTPUT
MAXIMUM
MODEL
PRESSURE
100MDCHP5*
100 psi (6.9 bar)
100MDC1
25 psi (1.7 bar)
100MDCHP20* 100 psi (6.9 bar)
100MDC2
25 psi (1.7 bar)
100MDC3
25 psi (1.7 bar)
100MDC4
25 psi (1.7 bar)
100MDC5
25 psi (1.7 bar)
APPROXIMATE LPD @ 50Hz – INNERMOST HEAD OUTPUT
MAXIMUM
MODEL
PRESSURE
100MDCHP5*
100 psi (6.9 bar)
100MDC1
25 psi (1.7 bar)
100MDCHP20* 100 psi (6.9 bar)
100MDC2
25 psi (1.7 bar)
100MDC3
25 psi (1.7 bar)
100MDC4
25 psi (1.7 bar)
100MDC5
25 psi (1.7 bar)
Injection check valve included with pumps rated 26-100 psi (1.8-6.9 bar).
*
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
10
PUMP TUBE
NUMBER
L
1
#1
0.2
0.3
#2
0.5
1.0
#3
1.1
2.2
#4
1.7
3.5
#5
2.5
5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0
PUMP TUBE
NUMBER
L
1
#1
0.6
0.9
#2
1.5
3.0
#3
3.3
6.6 13.3 20.0 26.6 33.3 40.0 46.6 53.3 60.0 66.6
#4
5.1 10.6 21.2 31.8 42.4 53.0 63.6 74.2 84.8 95.4 106.0
#5
7.6 15.1 30.3 45.4 60.6 75.7 90.8 106.0 121.1 136.3 151.4
www.stenner.com
FEED RATE CONTROL SETTING
2
3
4
5
0.6 0.9
1.2
1.5
2.0 3.0
4.0
5.0
4.4 6.6
8.8 11.0 13.2 15.4 17.6 19.8 22.0
7.0 10.5 14.0 17.5 21.0 24.5 28.0 31.5 35.0
FEED RATE CONTROL SETTING
2
3
4
5
1.8 2.7
3.6
4.5
6.1 9.1 12.1 15.1 18.2 21.2 24.2 27.3 30.3
6
7
8
9
1.8
2.1
2.4
2.7
6.0
7.0
8.0
9.0 10.0
6
7
8
9
5.5
6.4
7.3
8.2
10
3.0
10
9.1