Smarter tools CUT-40 Manual Del Usuario página 50

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Power Indicator Light is
off after turning on the
power supply.
Fan doesn't work after
turning on the power
supply.
Low Pressure Indicator
Light is on
No Air/gas check
function.
1. The light is broken.
2. Fuse is blown.
3. Not 230V Input
Voltage.
4. Power supply switch is
broken.
5. Controlling board or
cutter is damaged.
1. Fan is damaged.
2. Fan's ground lead is
broken.
3. Fan's blade is blocked
4. Transformer is
damaged.
1. No input compressed
air
2. Air/gas pressure valve
is adjusted to 0 or
broken.
3. Air/gas pressure
circuit is blocked
4. Air/gas pressure valve
is damaged
1. Air/Gas valve is
ruined.
2. Air/Gas circuit is
blocked.
3. Air/Gas check switch
is ruined
4. Ground lead is
broken.
5-2
1. Replace.
2. Replace.
3. Connect the 230V
Input cable.
4. Replace.
5. Examine and repair.
1. Replace.
2. Examine and repair.
3. Clean the block.
4. Replace.
1. Examine and repair.
2. Adjust or replace.
3. Clean the block.
4. Replace.
1. Replace.
2. Clean the block.
3. Replace.
4. Examine and repair.
Tabla de contenido

Solución de problemas

loading

Tabla de contenido