Primary Circuit Sizes to Achieve Maximum Current.
Minimum
Primary Supply
Primary
Model
Lead Size
Current and Duty Cycle
Current Size
(Factory Fitted)
(Volt/Amps)
2
CUT-40
12 AWG (3.3mm
)
230V/50A
35% @ 40A

3.4 Electromagnetic Compatibility

Extra precautions for Electromagnetic Compatibility may be required when this
Welding Power Source is used in a domestic situation.
A. Installation and Use - Users Responsibility
The user is responsible for installing and using the welding equipment according
to the manufacturer's instructions. If electromagnetic disturbances are detected
then it shall be the responsibility of the user of the welding equipment to resolve
the situation with the technical assistance of the manufacturer. In some cases
this remedial action may be as simple as earthing the welding circuit, see NOTE
below. In other cases it could involve constructing an electromagnetic screen
enclosing the Welding Power Source and the work, complete with associated
input filters. In all cases, electromagnetic disturbances shall be reduced to the
point where they are no longer Trouble-some.
B. Assessment of Area
Before installing welding equipment, the user shall make an assessment of
potential electromagnetic problems in the surrounding area. The following shall
be taken into account.
1. Other supply cables, control cables, signaling and telephone cables; above,
below and adjacent to the welding equipment.
2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of industrial equipment.