Testing Humidifier Operation; Controlling Your Humidity Settings - Honeywell HE240 Guía De Instalación/Manual Del Propietario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TESTING HUMIDIFIER OPERATION

Checklist
 Humidifier is level.
 Control wiring was reviewed using circuit diagram.
 Humidifier is plugged in.
 Feed line has no kinks.
 Drain line slopes continuously down and ends at floor drain.
 Water hose inside humidifier is connected to PerfectFLO
 Tubing from pressure switch is not kinked or pinched.
After installation use the following steps to check the humidifier operation:
1. Turn on the power and the water supply
2. Ensure the saddle valve is fully opened by turning the handle to the left (counter
clockwise) until there is resistance.
3. Turn the H8908 Humidistat to On and turn on the heat by setting the thermostat
to 10 ºF (6 ºC) above room temperature.
IMPORTANT
The furnace blower must be on to activate the humidifier.
4. Make sure that water is flowing out of the drain hose. If water does not flow, see
Troubleshooting Your Humidifier section.
5. Check for leaks.
6. Reset the thermostat and H8908 Humidistat to a comfortable setting for auto-
matic operation. (35% relative humidity is recommended.)
OPERATION

Controlling Your Humidity Settings

Your H8908 Humidistat controls your humidifier.
• Choose the humidity control setting using the combination of relative humidity/
outdoor temperature setting scale on your humidity control dial.
• Match the dial setting to the outdoor temperature to optimize the humidity level
while reducing the moisture condensation on your windows. See Table 2 on
page 16 to adjust the humidity control to the recommended setting.
NOTE: As the outside temperature drops, a lower humidity setting is recom-
mended to accommodate dewpoint effects. These settings should
reduce the accumulation of moisture and ice on windows and other
areas of the home.
• Adjust the humidity control setting to adjust for indoor activities such as cooking,
showering and clothes drying, which can cause excessive levels of humidity that
can accumulate moisture on your windows.
NOTE: If these activities persist for more than a few hours, set the humidity
control to the lowest setting to turn off the humidifier. If the condition
does not improve, ventilate your home to remove the moisture.
HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
15
water distribution tray.
69-2685ES—01
Tabla de contenido
loading

Este manual también es adecuado para:

He280

Tabla de contenido