Technogym RUN MED Manual Del Usuario página 28

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 193
too noisy
Problems in monitoring
heart rate with the chest
band
I r re g u l a r n o i s e f ro m
motor area
28
0SM00427AE-M1_UK.indd 28
Equipment not properly levelled.
Check.the.position.and.level.the.rear.adjustment.feet.
Damaged bearings.
Contact.the.technogym.technical.Support.Service.
Worn belt.
Contact.the.technogym.technical.Support.Service.
other transmitters situated nearby.
move. the. equipment. far. enough. away. to. stop. signal.
interference.(minimum.distance.between.two.units.80.
cm),.or.use.the.hand.sensor.
Strong interference sources nearby.
Find.the.interference.source.(e.g..an.electrical.domestic.
appliance).and.move.it.away,.or.move.the.equipment.
Worn heart rate monitor chest band.
Change.the.chest.band.
Chest band transmitter not making proper skin
contact.
Dampen.the.inside.of.the.chest.band.with.water.
Control panel not working properly.
Contact.the.technogym.technical.Support.Service.
Damaged transmitter.
Change.the.chest.band.
treadmill not centrally aligned.
align.the.treadmill.
run excite
02/07/2010 9.49.39

Hide quick links:

Tabla de contenido
loading

Tabla de contenido