too noisy
Problems in monitoring
heart rate with the chest
band
I r re g u l a r n o i s e f ro m
motor area
28
0SM00427AE-M1_UK.indd 28
Equipment not properly levelled.
Check.the.position.and.level.the.rear.adjustment.feet.
Damaged bearings.
Contact.the.technogym.technical.Support.Service.
Worn belt.
Contact.the.technogym.technical.Support.Service.
other transmitters situated nearby.
move. the. equipment. far. enough. away. to. stop. signal.
interference.(minimum.distance.between.two.units.80.
cm),.or.use.the.hand.sensor.
Strong interference sources nearby.
Find.the.interference.source.(e.g..an.electrical.domestic.
appliance).and.move.it.away,.or.move.the.equipment.
Worn heart rate monitor chest band.
Change.the.chest.band.
Chest band transmitter not making proper skin
contact.
Dampen.the.inside.of.the.chest.band.with.water.
Control panel not working properly.
Contact.the.technogym.technical.Support.Service.
Damaged transmitter.
Change.the.chest.band.
treadmill not centrally aligned.
align.the.treadmill.