8
INSTALLER
8.1
Menu installer settings
The following instructions are intended only for technical personnel specialised in heating units manufactured by
COLA.
Changing the parameters in a non-appropriate way can cause serious damage to people, the
To access the INSTALLER SETTINGS menu, press button P3 - MENU and use the scroll buttons to display the
item INSTALLER SETTINGS and then press button P3 - MENU. Use the scroll buttons to display access key 10
and press button P3 - MENU.again.
The various parameters can be displayed with the scroll buttons; access with button P3 - MENU, edit them with the
scroll buttons and exit with ESC.
It contains the adjustment parameters given below.
Parameter code
10-01
10-02
10-03
10-04
10-05
10-06
10-07
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
units and the environment. In this case, Cola s.r.l. declines any liability.
For increasing or decreasing auger OFF duration for all powers.
For increasing or decreasing fume extractor speed for all powers, by a
value of 5% for each unit.
Enable key lock.
Adjustment probe temperature setting ON/OFF delta (see parameter
10-07)
Stove shutdown delay.
Valid only in case of Standby set to ON.
For enabling self-calibration.
For selecting the probe on which stove adjustment is to be set:
- LOCAL PROBE: probe on stove and connected to the mainboard.
- RADIO PROBE: probe located on the radio remote control.