Flashing configuration

00
FIXED (the intermittent operation is carried out by the electronics of the flashing)
01
slow intermittent activation
02
slow intermittent activation when opening; quick intermittent activation when closing
NOTE: parameter
The flashing starts when there is a movement phase; you can have continued activation (for flashing
lights with electronics timed on-board) or controlled directly by the control unit (for flashing lights
with a simple lamp).
79 60

Duration courtesy light

00
OFF (deactivated)
01
PULSE (brief activation at the start of each operation)
02
ACTIVE DURING THE ENTIRE OPERATION
03
90
SECONDS OF ILLUMINATION AFTER THE END OF THE OPERATION
-
92
99
FROM 2 TO 9 MINUTES AFTER THE END OF THE OPERATION
-
80 00

Clock configuration

00
When the clock input is closed (ORO) it opens and then ignores all the commands
01
When the clock input is closed (ORO) it opens and accepts all the commands
If you choose par.
81 00

Closure enabling guaranteed

00
DEACTIVATED (NOTE: as a result par
01
ENABLED
This is enabled when you want to ensure that the door never stays open in unexpected situations;
for example due to an unwanted activation of the step-step command while moving away from the
gate while it is closing, or due to an undesired activation of the anti-crushing protection, the door
would remain open waiting for a new command.
After a time set by parameter
A5
from par.
) and then by a closing command.
The function will only be able to intervene if a STOP command has been given (from the push-button
pad) or the safety edge has intervened and the number set by parameter
control of the position has been lost (needs to be repositioned).
82 01

Waiting time to activate the closure guaranteed

01
90
SECONDS
-
92
99
from 2 to 9 MINUTES
-
86 01

Enabling thermal protection of the inverter

00
Disabled
01
Enabled
When this function is enabled, if the (estimated) temperature of the inverter exceeds the critical threshold,
it blocks the automation, with signal
temperature drops within safety levels.
7-
in simplified mode
A1 03
72 01
and
82
the control unit activates a pre-flashing of 5" (even if not enabled
tE P
the parameter is not displayed.
82
is not displayed)
on the display; operation resumes automatically when the
a2
, has been exceeded, or
37