72 00

Limit switch enabling

00
no limit switch connected
01
opening limit switch connected
NOTE: parameter
isible only if you set
73 03

Safety edge 1 configuration

00
NOT PRESENT
01
SWITCH, only reverses when opening
02
8k2, only reverses when opening
03
SWITCH, always reverses
04
8k2, always reverses
74 01

Safety edge 2 configuration

00
NOT PRESENT
01
SWITCH, only reverses when closing
02
8k2, only reverses when closing
03
SWITCH, always reverses
04
8k2, always reverses
If you choose
safety protection and it uses input INP2 (terminal block no.24) for limit switch opening wing 2.
76 00

1st radio channel configuration

77 01

2nd radio channel configuration

00
PP
01
PEDESTRIAN
02
OPEN
03
CLOSE
04
STOP
05
COURTESY the relay is only driven by the radio, it is deactivated in normal operation
COURTESY PP (turn light on-off) the relay is only driven by the radio, it is deactivated in
06
normal operation
07
PP with safety confirmation (via radio function no. 2)
08
PEDESTRIAN with safety confirmation (via radio function no. 2)
09
OPEN with safety confirmation (via radio function no. 2)
10
CLOSE with safety confirmation (via radio function no. 2)
Activation of the radio control with confirmation (programming with values
The radio control with the confirmation of the request is used to prevent the incorrect pressure on a
button of the remote control being able to activate the automation; this feature is enabled so that it
is free and independent for both functions PR1 and PR2 available on the receiver coupling.
Example: programming
under function 1 of the radio and the CHB button of the remote control stored under function 2 of the
radio, activating the CHA button starts a countdown, and only if, the CHB button is activated within
a period of 2" then the "step-by-step" command is actually executed. On the other hand, if CHB is
activated the pedestrian control opening is immediately activated.
40
8-
in simplified mode,
A1 03
.
A1 03
72 01
and
76 07
the parameter is not displayed: COS2 is not managed as a
77 01
and
, with the CHA button of the remote control stored
07
08
09
10
-
-
-
)
Tabla de contenido