OPERATION AND LOGIC

IGNITION
Once the previously listed points have been checked, press key 1 for three seconds to ignite the stove. During ignition, the stove will check for
a ame for a period of 15 minutes. When the right temperature is reached, the stove will switch from ignition to PREPARATION.
PREPARATION
During the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK
WORK
In the work phase, the stove switches to the Set Power de ned by the user, heating the room until Set Thermostat is achieved. See next
heading.
SET THERMOSTAT
The ambient Set thermostat can be set using keys 4 and 5, from LOW TA - 7°C - 37°C - HOT. If the value is between 07°C-37°C, the stove checks
the ambient temperature by means of an on-board probe. Once the set temperature has been reached, the stove automatically reduces the
power, guaranteeing best comfort and reducing pellet consumption: this process is called "modulation".
LOW TA / HOT
If the Set Thermostat is " LOW TA " (set under the 7° threshold), temperature checking is entrusted to the additional thermostat contact, thus
bypassing the on-board temperature probe.
If the contact is open (ful lled), the stove works at minimum power.
If the contact is closed (request), the stove works at the set power.
If the setting is on "HOT" (set above 37°C), the stove only works at the set power, thus bypassing the external contact and the temperature
probe.
SET POWER
Set Power has 5 operating levels. The power can be changed with keys 2 or 3.
Power 1 = minimum level - Power 5 = maximum level.
Press key 6 to exit and save the change.
BLOW
During the work phase, the stove cleans the burn pot at regular intervals, called "BLOW".
When this procedure starts, a message is displayed. During the "BLOW" procedure, the pellet feed slows down and the fumes motor speeds up.
After cleaning, the stove resumes operation in normal conditions.
SWITCH OFF
Press key 1 for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-o phase, blocking the supply of pellets.
The ue gas exhaust motor and the hot air ow motor will remain on until the stove temperature has dropped below the safety settings.
REIGNITION
The stove can only be re-ignited if the temperature of the exhaust fumes is lower than the preset threshold and the minimum safety time has
passed.
DO NOT USE ANY FLAMMABLE LIQUIDS FOR IGNITION!
DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE
FILLING PHASE!
IN THE EVENT OF CONTINUED FAILURE TO LIGHT, CONTACT AN AUTHORISED TECHNICIAN.
IT IS PROHIBITED TO USE THE APPLIANCE WITHOUT THE PARTITION AND/
OR FLAME GUARD SEE FIGURE ON SIDE . REMOVAL WILL COMPROMISE THE
SAFETY OF THE PRODUCT AND RESULT IN THE IMMEDIATE NULLIFICATION
OF THE WARRANTY PERIOD. IN THE CASE OF WEAR OR DETERIORATION,
REQUEST AFTER SALES ASSISTANCE TO REPLACE THE PART REPLACEMENT
IS NOT COVERED BY THE WARRANTY AS THE COMPONENT IS SUBJECT TO
WEAR .
ENGLISH