Adjustments; Adjusting Gas Solenoid Valve - Angelo Po 0G1FR3G Manual De Uso

Ocultar thumbs Ver también para 0G1FR3G:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

3 - Check that the burner is switching on correctly
and its combustion.
4 - Check the gas pressure and flow-rate at mini-
mum and maximum settings and adjust if nec-
essary (see page 22).
5 - Check that the safety thermocouple is working
correctly.
6 - Check that there are no gas leaks.
RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment,
activate all the safety devices provided
and decide whether staff at work and
those in the vicinity should be informed.

ADJUSTING GAS SOLENOID VALVE

IT
Important
GB
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
DE
dure has been carried out (see page 21).
FR
Carry out this operation as described on both the
gas solenoid valves.
ES
Natural gas
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Undo the screw (B) of the pressure connection.
4 - Connect the pressure gauge (C) to the pres-
sure test point.
5 - Unscrew the cap (D) and if necessary fit the
spring (F) and adjuster screw (E) (supplied on
request).
6 - Turn the gas supply tap back on.
English
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.

ADJUSTMENTS

In particular, turn off the gas supply tap and
prevent access to all devices which might
cause unexpected health and safety haz-
ards if turned on.
Before making this adjustment, check that
the gas supply pressure is the same as the
rated pressure for the type of gas in use
(see table at back of manual).
- 22 -
7 - Check that the nameplates specify the correct
gas for the country of use.
A
C
B
8
D E F
IDM-39603311600.tif
Tabla de contenido