34 |
According to the international provisions, during the
assembly of the appliance, place a device before the
appliance itself that allows the unit's disconnection
from the mains circuit in an omnipolar way; this device
must have an opening of contacts of at least 3 mm.
Attention!
The yellow-green ground cable must never be broken.
ELECTRICAL CONNECTION
In series S700 models, the appliance is supplied with the
power lead. For models without the lead, connect the
appliance to the power network as indicated, connect the
appliance to the mains as shown (see Fig. 4 and Fig. 5)
1) Install, if not present, a disconnecting switch (A) close
to the appliance with a thermal magnetic release and
differential locking
2) Open the doors (B), if present, and loosen the screws (C)
to disassemble the panel (D).
3) Connect the disconnecting switch (A) to the terminal
EN
board (H) as shown in the figure and in the electrical
diagrams at the end of this manual. The chosen
connection cable must have features similar to the
H07RN-F type with an operating temperature of at least
80 °C and have a section suitable to the unit (see the
Technical Data table).
4) Pass the cable through the passage and tighten
the cable stopper, connect the conductors in their
corresponding position to the terminal board and
attach them. The yellow-green ground conductor must
be longer than the others so that, in the event that
the cable stopper breaks, it disconnects itself after the
voltage cables.
Equipotential
The appliance must be connected to an equipotential
system. The connection terminal is close to the entrance
of the power supply cord.
It is marked by the following symbol:
Attention!
The manufacturer is not responsible and will not
reimburse, under the guarantee, damages due to the
improper installation and installation that does not
conform to these instructions.
Important
Before putting it in operation, test the equipment
to evaluate the operational conditions of each
component and single out any possible anomalies.
During this phase, it is important that safety and
hygiene conditions are strictly followed.
Carry out the following controls to perform the test:
APPLIANCE TEST
1) Check that the main voltage is in conformity with the
appliance voltage
2) Use the automatic disconnecting switch to check the
electrical connection
3) Check the proper operation of safety devices.
After testing, if necessary, train the users so that they
understand all necessary skills to operate the equipment
in safe conditions, according to the regulations in force in
the country in which the equipment is to be used.
USE INSTRUCTIONS
This type of apparatus is to be used for commercial
applications, for example restaurant kitchens,
canteens, hospitals and commercial businesses, such
as bakeries, butchers, etc., but not for continual mass
production of food.
ATTENTION!
Use the appliances under supervision and never
operate while empty.
Pilot lights indicate if every unit is on or off.
The appliance does not need particular adjustment
interventions by specialized people except for the
regulations made during the user's operation.
Use only the accessories recommended by the
manufacturer.
During the initial uses of the appliance, an acrid or
burning smell may be detected. This will disappear
after two or three uses.
After use, the areas are hot for a certain amount of
time (residual heat). Avoid resting your hands on them
and allowing children to get too close! This appliance
cannot be used by people (including children) with
impaired skills or without experience and knowledge
unless under the supervision of a person responsible
for their safety who provides precise instructions
about the use of the unit.
Keep children under supervision to make sure that
they don't play with the unit.
These are very important regulations; if they are
neglected, the appliance may not perform properly or
the user may be placed at risk.
OPERATION
Before using the unit for the first time, clean the tank
properly (see the paragraph "Care of the appliance").
Check the appliance connection and put it into service
following the instructions.
Switching on and off (Fig. 6)
Activate the main switch upstream the appliance. Turn on
the switch (A) by placing it to the "I" position; the pilot light
inside it will switch on, which means the heating elements
are connected. Position the switch (A) to the "0" position
and turn off the main switch to switch off the appliance.