DITEC Flash C Manual De Instalación, Manutención Y Utilización página 32

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Operation
7
Partial opening
8
During operation
9
Activation of the manual
release lever
EC DECLARATION OF CONFORMITY
Manufacturer: DITEC S.p.A.
Address: via Mons. Banfi, 3 - 21042 Caronno P.lla (VA) - Italy
declares that the product: FLASH
complies with the essential requirements of the following
EC directives:
- EMC Directive 89/336/EEC
- Machinery Directive 98/37/EC
- Construction Products Directive 89/106/EEC
complies with the following characteristics of EN 13241-1
standard (Annex ZA):
All right reserved
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes
APPLICATIONS
Service life: 5 (minimum 5 years of working life with 600 cycles a day)
Applications: HEAVY DUTY (for industrial and commercial access with heavy duty use).
• Service class, running times, and the number of consecutive cycles are to be taken as merely indicative having been statistically
determined under average operating conditions, and are therefore not necessarily applicable to specific conditions of use. During given
time spans product performance characteristics will be such as not to require any special maintenance.
• The actual performance characteristics of each automatic access may be affected by independent variables such as friction,
balancing and environmental factors, all of which may substantially alter the performance characteristics of the automatic access or
curtail its working life or parts thereof (including the automatic devices themselves). When setting up, specific local conditions must be
duly borne in mind and the installation adapted acwireingly for ensuring maximum durability and trouble-free operation.
Default
The door opens completely
The panel does not stop at end
of stroke
The door is not released (the
panel does not move to the
partial opening position)
- Factory production control (Pass)
- Release of dangerous substances (Pass)
- Safe opening (Pass)
- Mechanical resistance and stability (Pass)
- Operating forces (Pass)
Approved body: C.S.I. S.p.A.
Registration number: CPD/0497/049/05
Address: Viale Lombardia, 20 - 20021 Bollate (MI) - ITALY
Caronno Pertusella, 01/05/2005
- 32 -
Cause / corrective measure
• The partial opening (connection 1 - 20)
has been improperly carried out
• The RP potentiometer is connected to a
value which is too high
• The limit switch contact is short-circuited
• A mechanical default has occurred in the
limit switch or in the brake
• The release cable for the motor brake
release is broken or adjusted improperly
0DT721 01/05/2005
Fermo Bressanini
(Chairman)
DITEC S.p.A.
Tabla de contenido
loading

Tabla de contenido