Parker PSE Serie Manual De Uso página 18

Ocultar thumbs Ver también para PSE Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
English
5.5 Visualization of temperature probes
On display appear the dew point temperature as defoult.
To view other temperatures, proceed as follows:
set
Press the button
to enter on menu of the direct parameters.
to fi nd the parameter " Ai"
Use the arrows
or
set
Press
to enter.
Use the arrows
or
chosse the sensor.
b13 = dew point temperature sensor;
b5 = evaporation temperature sensor;
b8 = condensation temperature sensor;
Once chosen wait a few seconds to see the value read.
esc
Press
to exit.
set
HiSt
b5
....
set
0.0
5.6 Remote ON/OFF
Press the buttons
menu "PAr" .
set
to enter on menu " CF9"
Press
Use the arrows
set
Press
to enter.
Use the arrows
ON : remoto ON;
OFF: remoto OFF.
set
Press
to confi rm.
esc
Press
to exit.
Al
set
esc
b13
set
4.0
PSE 120-350
esc
set
and
together to enter on general
to fi nd the parameter " A7 ".
or
or
to choose:
esc
set
PAr
set
esc
CF9
set
esc
C_F
A7
set
esc
0n
OFF
5.7 CYCLING function
esc
set
Press the buttons
and
together to enter on general
menu "PAr" .
set
Press
to enter on menu .
to fi nd the parameter " C4C".
Use the arrows
or
set
Press
to enter on menu .
to fi nd the parameter " C7 "
Use the arrows
or
set
Press
to choose:
ON : continuous;
OFF: cycling.
set
Press
to confi rm.
esc
Press
to exit.
esc
set
PAr
set
esc
CF9
C4C
esc
C7
esc
On
OFF
4/12
set
set
Tabla de contenido
loading

Este manual también es adecuado para:

Pse 120Pse 140Pse 180Pse 220Pse 260Pse 300 ... Mostrar todo

Tabla de contenido