Taurus ONTIME RAPID Manual De Instrucciones página 26

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
- If any anomaly is detected, check the following
table:
Anomalies
The pressure release
selector valve makes
a noise and does not
release steam after the
cooker is heated.
The safety valve relea-
ses steam or liquid.
Steam is coming out of
the safety grille.
The lid does not close
properly.
Steam is escaping
from underneath the lid
- Take the appliance to an authorised technical
support service if problems arise. Do not try to
dismantle or repair without assistance, as this may
be dangerous.
Ecology and recyclability of the product
- The materials of which the packaging of this
appliance consists are included in a collection, clas-
sification and recycling system. Should you wish to
dispose of them, use the appropriate public recycling
bins for each type of material.
The product does not contain concentrations of
substances that could be considered harmful to the
environment
This appliance complies with Directive 97/23/EEC on
Pressure Vessels.
Manual Ontime Rapid.indb 26
Causes
(1) Blockage of the pressure
release selector valve
(2) Blockage of the air
release pipe
(3) Cooking without liquid
(4) The hob is inclined
(1) Blockage of the air
release pipe
(2) The pan has been
overfilled
(3) The heat source is too
strong
The grille's safety system
is operating correctly. The
other safety systems are not
working normally.
The lid has become
misshapen.
(1) Malfunctioning of the
pressure release selector
valve and safety valve
(2) The sealing joint is not
properly fitted
(3) Damaged joint
(4) Blockage of the O-ring
(5) Lid closed badly
Solutions
(1) Clean the pressure release
selector valve
(2) Remove the dirt
(3) Immediately turn off the hob,
remove the cooker, reduce the
pressure and check the cooker.
(4) Heat the cooker on a flat,
stable hob
(1) Remove the dirt
(2) Reduce the filling quantity
(3) Adjust the heat source to the
steam being released by the pressu-
re release selector valve
Remove the appliance from the sou-
rce of heat. Once cold, check all the
safety systems. Request assistance
from a technical repair service.
Change the lid.
(1) Remove the dirt from the
pressure release selector valve and
safety valve
(2) Fit the sealing joint correctly
(3) Replace the sealing joint
(4) Clean the sealing joint
(5) Close the lid correctly
28/05/14 17:38