6
en | Installation Manual
US Gang Box
4 Screw Custom
CAUTION!
Do not drill! This is the tamper lens.
NOTICE!
Card readers are to be used with a listed access control unit
whose power supply is UL Listed Class 2 or equivalent.
WIRING INSTRUCTIONS
The ARD-AYQ12 is supplied with an 18 inch (45 cm) pigtail,
having a 6-conductor cable.
To connect the reader to the controller, perform the following
steps:
1.
Prepare the reader cable by cutting the cable jacket back
1
2.
Prepare the controller cable by cutting the cable jacket
back 1
(1,3 cm).
| V 1.2 | 2009.09
There are two hole indicators on the back
of the metal cover specifically for the US
Gang Box. (Shown marked as A)
There are four indicators on the back.
(Shown marked as B)
inches (3,4 cm) and strip the wires
1/4
inches (3,4 cm) and strip the wires
1/4
ARD-AYQ12
inch (1,3 cm).
1/2
inch
1/2
Bosch Sicherheitssyteme GmbH