6. Maintenance; 6.2 Rechargeable Battery Replacement; Spare And Wearing Parts - Bosch KTS 340 Manual Original

Ocultar thumbs Ver también para KTS 340:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

en
16 | �TS ��� | Maintenance
6.
Maintenance
6.1
Cleaning
Only clean the housing and display of the KTS 340 with
a soft cloth and neutral cleaning agents. Do not use
abrasive cleaning agents or coarse workshop cloths.
6.2
Rechargeable battery replacement
Danger due to high voltage!
If the KTS 340 is open and the cover (Fig. 4,
Pos. 5) of the LCD background illumination
has been removed, life-threatening high volt-
age may occur.
Never remove the cover of the background
illumination.
Incorrect handling carries a risk of ignition,
bursting or combustion!
Batteries must not be heated, burned, short-
circuited, mechanically damaged or charged
with excessively high currents or reverse
polarity.
Suitable extinguishing agents: Water,
CO
, sand.
2
!
Only use the nickel-metal hydride batteries specified
for the KTS 340. We recommend batteries with a
battery capacity of 2000 mAh to 2300 mAh. Always
replace all the batteries. Dispose of old batteries in
accordance with the applicable legislation.
1. Switch off the KTS 340.
2. Slacken the screws (5x, Fig. 4, Pos. 1) on the back
of the unit and detach the housing cover (Fig. 4,
Pos. 2).
3. Take out the battery compartments on the left and
right and set down on the metal housing (Fig. 4,
Pos. 3).
4. Take out the old batteries (Fig. 4, Pos. 4).
5. Insert new batteries (8x), taking care to ensure
correct polarity.
6. Re-insert the battery compartments in the unit.
!
Take care not to trap the leads to the battery com-
partment when fitting the back panel.
7. Re-fit the back panel of the unit.
8. Screw the screws (5x) back in.
|
1 689 989 072
2010-04-06
1
5
4
3
Fig. 4:
Rechargeable battery replacement
6.�

Spare and wearing parts

Description
System tester KTS 340 (green)
Power supply unit
Power supply lead
USB connecting cable, 3 m
OBD diagnostic cable, 3 m
<)
4-pole UNI connecting cable
<)
Stylus (3x)
Case
Measuring lead, red
<)
Measuring lead, blue
<)
Measuring lead, yellow
<)
Ground cable, black
<)
Test prod, red (2x)
<)
Connection terminal, black
<)
Adapter insert
Batteries (8x)
Wearing part
<)
2
4
3
Order number
1 687 023 549
1 687 022 890
1 684 461 161
1 684 465 562
1 684 465 557
1 684 463 539
1 683 083 007
1 685 438 626
1 684 430 065
1 684 430 066
1 684 430 067
1 684 430 068
1 684 485 035
1 684 480 022
1 688 000 355
1 687 335 031
Robert Bosch LLC

Capítulos

Tabla de contenido
loading

Tabla de contenido