Bottle Data; Bottlepressure Calibration - Sun BREEZE II Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 148

BOTTLE DATA

N.B. This menu is reserved for use by the technician performing final testing. It contains the
maximum safety threshold value; therefore, the bottle data may not be changed for any reason.
For assistance, call the Service Center.
From the CALIBRATION MENU:
Select BOTTLE SCALE and the following screen is displayed:
Select BOTTLE DATA. The following screen will be displayed:
Use the arrow keys and the number pad to change the Max, Min, and Tare values. Then select
PREVIOUS MENU and press ENTER.
Press START to confirm saving the data or STOP to exit without saving.

BOTTLEPRESSURE CALIBRATION

Remove the plastic shield on the back of the machine to access the bottle. Close the blue tap
of the bottle, and the tap on the lower side of the hig-pressure filter (3, fig11). Slowly unplug the
blue pipe from the bottle to get the pressure in the bottle transducer to 0 bar. Turn the machine
on. From the CALIBRATION MENU:
Select BOTTLE PRESSURE and the following screen is displayed:
Press START to zero.
INSTRUCTIONS MANUAL
BOTTLE SCALE
BOTTLE PRESSURE
BOTTLE TEMPERATURE
CALIBRATION
<BOTTLE DATA>
PREVIOUS MENU
Max
xxxxx g
Min
xxxxx g
Tare
xxxxx g
PREVIOUS MENU
SAVE DATA:
Press START.
To exit:
press STOP
BOTTLE PRESSURE
BOTTLE PRESSURE
BOTTLE TEPERATURE
ZERO LEVEL
Unplug the blue pipe
Levels xxxxx
Press START
-32-
Tabla de contenido
loading

Tabla de contenido