14
USE
☞The requirements for the ingress degree (dust catego-
ry M) have only been proven for dry vacuuming.
•
Be sure that switch is in off position (0) OFF and
connect the machine to a suitable socket.
DRY VACUUMING
Class M vacuum cleaners are suitable to vacuum dry,
non-combustible dusts with workplace limit values of ≥
0,1 mg/m3.
Inserting the filters: (fig. 7)
(A) Paper bag .
(B) )Cartridge Filter .
(C)Filter in polyurethane foam (only for wet & dry
models)
WET VACUUMING
For wet & dry models, before cleaning up liquids, make
sure that the paper bag (A) and the cartridge filter (B)
have been removed.
Inserting the filter: (fig. 8)
(C) Filter in polyurethane foam (only for wet & dry
models)
• The machine must be always kept on horizontal
bases, in a safe and stable way.
• Insert the suitable filters for the proper use.
•
Never use the appliance without filters .
• Use the most suitable accessories for the requested
usage.
• Put switch on (-) ON position in order to start the
machine.
☞NOTE: An adequate ventilation rate (dust category
class M ) must be provided for when the outgoing air
is circulated.
•
WARNING: DO NOT connect power tools to outlet
(when using the vacuum for wet pick up.
☞NOTE: Plug vacuum into residual current device (RCD)
protected outlet when using the vacuum for wet pick
up.
• When job is over, switch off (0) OFF and keep away the
plug from the socket.
BLOWER FUNCTION
•
CAUTION: function not usable if the appliance is
used to dry vacuum harmful dust.
The appliance can also be used as a blower: remove the
air outlet grid 10 by pressing gently on the closure
tab, remove the hose from the inlet 3 and then insert
the bayonet cap of the hose into the blower outlet
situated inside the lid, behind the air outlet grid, as
shown in fig.4.
• When job is over, switch off (0) OFF and keep away the
plug from the socket.
START UP
(0) OFF, SWITCH OFF
(I) ON, MANUALLY OPERATED: VACUUMING
AUTOMATICALLY
CONNECTING ELECTRIC POWER TOOL
TO SOCKET - SOCKET FOR TOOLS
MAX. 2200 W
CONNECTING ELECTRIC POWER TOOLS:
•
WARNING:
- Observe the maximum connected loads for the ap-
pliance socket (Refer to the SPECIFICATIONS.)
- Make sure that both the cleaner and the electric
power tool are switched off before connecting or
disconnecting.
- To connect an electric power tool, open the cap
and insert the power tool plug into the socket of
the cleaner.
- Rotate the switch lever to the "AUTOMATICALLY"
position.
- Switching ON and OFF of the connected electric
power tool simultaneously brings the cleaner
switching on and off action.
At the end of the cycle, the filter shake function will
be activated for about six seconds.
- After use, disconnect the power tool from the so-
cket of cleaner.
- Switch off the cleaner after use.
• Even when rotate switch to position (I) ON
electric tool socket is live.
To clean the filter manually, set the selector
to the symbol of the filter cartridge.
OPERATED
WITH
, the