1.- Technical data
Voltage:
230V~ 50-60Hz
Output:
1 potential free relay
Output power:
Operation modes: (a) Switch o (b) Time delay switch
Radio frequency: 868MHz
Range:
Approx. 30m inside buildings. 100m free field space conditions
Building
construction
transmission path between the sensor and actuator device, attenuates
the signal strength so distance range is reduced.
Pay attention to metallic objects in between sensor and actuator
device that could reflects wireless signal, concretely when they are
very closed to them.
Operation mode and configuration selectors
Push button LED
Operation mode selector
Configuration mode selector
Operation temperature:
From 0ºC to +45ºC
2.- Installation scheme and connection
2.1.- Installation
To improve communication range (distance):
-
Try to place the antenna wire straight as possible, not touching any
other wire or electronic insert
-
Install 1 m distance from other wireless device
-
Do not cut the antenna wire.
WIRELESS ASTUATOR
2.300 W/VA
1.000 VA
materials
or
furniture
in
the
DIN RAIL RELAY
(Ref. 8130.6)
ENG - User Manual
2.2.- Connection
Important: Disconnect the mains voltage power when installing.
Basic installation scheme
wireless
3.- Configuration
3.1.- Configuration modes
Configuration modes can be selected through the configuration mode selector:
3.2.- Mode P (P=Programming)
1.
Set the selector switch of the actuator to "P". The push button LED flashes
green.
2.
Actuate the push button of the actuator. The push button LED switches over
from green flash light to continuous light.
Note: There is 3 minutes timeout for the linking process, during this time,
LED is continuously green and waiting a sensor device to be programmed.
After that, the LED flashes green again.
3.
Set the transmitter sensor device into link configuration mode.
4.
After a successful programming, the push button LED (actuator) starts to
flash again. If programming fails, the push button LED is lighting
permanently.
5.
Returning to the operating mode: Set the operation mode switch of wall
transmitter and actuator to "F" or "Rpt." position.
If a further transmitter should be programmed on the same actuator, return to
operating mode and. Repeat the described procedure above.
Normal operation plus Repeater (Rpt.) = Repeater
Normal operation (F) = Standard
Teach in connection (P) = Programming
Erase connection (B) = Erase
Erase all connections (Rst.) = Erase All (Reset)