Maintenance
5.3.2
Checking the battery capacity
1. Press the button to display the battery capacity on the re-
chargeable battery.
2. Read the battery status indicator.
3. If the battery capacity is insufficient for the planned period
of service:
Replace or charge rechargeable battery (see section 5.3.3
on page 22).
5.3.3
Replacing or charging the rechargeable battery
CAUTION
!
A short circuit could damage the rechargeable battery!
Make sure that the battery terminals do not come into
contact with metal during storage.
Removing the rechargeable battery:
1. Fold up carrying system if necessary.
2. Push battery lock button. Ensure that the rechargeable bat-
tery does not fall down.
3. Remove rechargeable battery.
Inserting the rechargeable battery:
1. Fold up carrying system if necessary.
2. Position the rechargeable battery at an angle in the battery
compartment and then fold it in until it snaps audibly into
place.
Charging the battery:
NOTICE
i
i
Always disconnect the charger from the power supply
if not in use.
1. Check to make sure that voltage of mains supply is correct.
The operational voltage of the power supply unit must
match the mains supply voltage.
2. Connect charger to power supply unit.
3. Connect the power supply unit to the mains supply.
4. Position the rechargeable battery at an angle in the charger
and then fold it in until it snaps audibly into place.
5. Wait for the end of the charging process.
6. When the rechargeable battery is fully charged, push the
battery lock button and remove the battery.
7. Disconnect the power supply unit and charger from the
mains supply.
5.3.4
Replacing the filter
WARNING
!
No protection without filter!
Do not use the device without filter.
CAUTION
!
Damage to fan unit due to penetration of particles!
Make sure when you remove the filter that no particles
enter the device through the suction inlet.
NOTICE
i
i
The filter changing process may differ depending on
the filter type used.
22
Particle filter
Removing the filter:
02633412.eps
1. Push filter lock button.
2. Fold out filter together with the splash guard cover (Figure
A).
3. Remove used filter (Figure B).
Inserting the filter:
1. Check rubber seal on filter for damage.
2. Insert new filter into splash guard cover.
3. Position filter together with splash guard cover at an angle
into the fan unit.
4. Fold in filter with splash guard cover until it snaps audibly
into place.
Gas or combination filter
Removing the filter:
02833412.eps
1. Push filter lock button.
2. Fold out filter together with the splash guard cover (Figure
A).
3. Dismantling the splash guard cover:
a. Press on the centre of the upper splash guard cover
edge until it snaps out.
b. Fold out splash guard cover (Figure B).
Inserting the filter:
1. Check rubber seal on filter for damage.
2. Place splash guard cover with its lower edge at an angle on
the filter.
3. Push on splash guard cover until it snaps audibly into
place.
4. Position filter together with splash guard cover at an angle
into the fan unit.
5. Fold in filter with splash guard cover until it snaps audibly
into place.
5.3.5
Checking the flow rate and warning devices
1. Make sure that a filter is inserted (see section 5.3.4 on
page 22).
2. Connect the plug-in connector of the breathing hose to the
fan unit.
A
A
Dräger X-plore 8000
B
02733412.eps
B
02933412.eps