Fault; Troubleshooting - Angelo Po 0N1CP1GH Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

The appliance has been tested before being put
into service. The information provided below
is intended to assist in the identifi cation and
correction of any anomalies and malfunctions
which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical
knowledge or skill is required, and so they must
only be carried out by qualifi ed staff with reco-
gnised experience acquired in the specifi c sector
of operation.
Faults
Smell of gas
The pilot light does not ignite.
The pilot light goes out.
The fl ame is yellow.
When the water control
knob is turned to 1 (auto-
matic rapid fi lling), water is
supplied continuously, until it
overfl ows.
When the water control knob
is turned to 1 (automatic
rapid fi lling), no water comes
out of the tap.
When the water control knob
is turned to 2 (Slow automa-
tic top-up), slow fi lling does
not take place.
3269830_ut_GB_rev.2

FAULT

TROUBLESHOOTING

For all requirements contact the agents or the
headquarters of Angelo Po which can be found
in the contacts section of the website http://
www.angelopo.com.
Causes
Occasional leak because fl ame
has gone out.
The spark ignition devices are
not working.
Air in pipelines due to long
period out of use.
The thermocouple has not
warmed up enough.
Burner dirty, heat exchange
pipes clogged, condensation
drips.
Blockage in pressure switch
circuit..
Pressure switch faulty.
Filler solenoid valve faulty.
Pressure switch connection not
made correctly.
Water connection not made
correctly.
Water level maintenance sole-
noid valve connection not made
correctly.
Water level maintenance sole-
noid valve faulty.
- 13 -
Important
Remedies
Turn off the gas supply tap and
ventilate the room.
Check that the ignition devices are
in good working order .
Contact the after-sales service.
Make more attempts to light the
Make more attempts to light the
Contact the after-sales service.
Contact the after-sales service.
Check the pressure switch con-
nection.
Contact the after-sales service.
Check the water connection.
Contact the after-sales service.
Check the solenoid valve connec-
Contact the after-sales service.
fl ame.
fl ame.
tion.
ENGLISH
GB
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0t1cp1gh1n1cp2gh1t1cp2gh

Tabla de contenido