- English -
Start-up (
Filtral UVC 700 / 1200)
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Grounding instructions
!
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord
having an appliance-grounding conductor and a grounding plug. The plug must be plugged into an appropriate
outlet that is installed and grounded in accordance with all local codes and ordinances.
Warning
Improper connection of the appliance-grounding conductor can result in a risk of electric shock. Check with a
qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. Do not
modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified
technician.
Attention! Sensitive electrical components.
!
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains.
The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
● The indicator lamp (A) indicates the ON/OFF status of the UVC lamp.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the
units and installations (switch off and disconnect from the power supply) before reaching into the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
!
CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
• Never operate the UVC lamp outside its casing.
• Never operate the UVC lamp in a casing that is defective.
Danger: Ultraviolet radiation.
!
Do not expose eyes to lamp rays.
Disconnect power before servicing or replacing lamp.
Replace lamp only with lamp rated 7 watts (UVC 700) 9 watts (UVC 1200):
Warning: To reduce the risk of electric shock - Connect only to a circuit that is protected by a ground-fault circuit
interrupter (GFCI)
For indoor and outdoor household use
A
6