- English -
Storage/Winterization
● Put the unit out of operation at water temperatures below 32 °F (0 °C) or, at the latest, when freezing temperatures are
to be expected.
● Thoroughly clean the unit, check for damage.
● Store immersed in water or filled with water in a frost-free place. Do not immerse the power plug in water!
● Ensure that the storage place is inaccessible to children.
Wear parts
The UVC lamp, the different filters and the rotor are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority. Only dispose of
the UVC lamp by using the system provided from your local municipal authority.
Troubleshooting
Issue
Cause
The unit is not
Power supply not connected
operating
Insufficient flow,
Flow regulator excessively throttled
Cloudy water
Nozzle blocked
Excessive pressure losses in the
tubing
Intake openings blocked
Filters clogged
Rotor blocked
Pond extremely dirty
Quartz glass tube soiled
UVC lamp does
Lamp overheated. The temperature
not light up
switch has switched off the lamp
UVC lamp defective
UVC lamp is not correctly seated in
the socket
Unit switches
Water temperature too high
off after a short
running period
Solution
Connect pump power supply
Set flow regulator
Unscrew and clean the nozzle insert
Reduce tubing length and connecting parts to a
minimum, route hoses as straight as possible
Clean housing
Clean filters
Clean rotor
Remove algae and leaves from the pond, change the water
Remove UVC clarifying unit and clean the quartz glass tube
The lamp will automatically switch on again once cooled down
Replace the UVC lamp
Correctly insert the UVC lamp into the socket
Maximum water temperature: +95 F° (+35 °C)
12