Schulz Compact Serie Manual De Instrucciones página 84

Ocultar thumbs Ver también para Compact Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Procedure
Check oil level
Change lubricant oil
Replace the conventional air filter element
Replace the vehicular air filter element
Check the air filter element restriction level
compressors up to 40hp
Replace the oil filter
compressors up to 40hp
in compressors up to 15hp
in compressors up to 15hp
Replace air/oil
separator element
in compressors up to 15hp
Check the air/oil separator element restriction level
Clean the radiator and the condenser externally
Check for oil leaks
Inspect the safety valve
Check the condition and tightness of hoses
Tighten screws
Check electrical, switch and motor connections.
Clean the filter air inlet on the compressor
Compressor cleaning
Clean the air filters of the electrical box
Check voltage and tcondition of the belt(s)
Lubricate the motor bearings (according to motor nameplate)
Check the coalescing pre-filter restriction level
Replace coalescing pre-filter element
Check operation of the automatic air purge (when applicable)
Replace nylon tubes
ATTENTION
If the compressor remains stopped for a period equal to or exceeding six months, it will be required and the
customer's responsibility to replace the filters and oil.
Daily
mineral 1000
mineral 4000
synthetic 8000
with mineral oil
with synthetic oil
with mineral oil
with synthetic oil
TABLE 13.3 - PREVENTIVE MAINTENANCE PLAN
Weekly
1000h
2000h
* (1)
* (8)
*
* (5)
* (2) (9)
* (2)
* (5)
*
*
*
*
*
*
*
*
*
84
4000h
8000h Annually
* (8)
* (8)
*
* (6)
* (6) (9)
* (6)
*
*
* (7)
*(11)
*
When
Required
*
*
*
*
*
* (4)
*
* (4)
*
*
*
*
*

Hide quick links:

Tabla de contenido
loading

Tabla de contenido