Safety Information - Master MH-80-OFR Manual Del Usuario E Instrucciones De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WARNING
The products described in this manual are
kerosene direct-fired, forced air heaters. Kerosene
forced air heaters are primarily intended for use for
temporary heating of buildings under construction,
alteration or repair. Direct-fired means that all
of the combustion products of the heater enter
the heated space. This appliance is rated at 98%
combustion efficiency, but does produce small
amounts of carbon monoxide.
DANGER
LEAD TO DEATH!
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation in
accordance with the instructions in this manual can
result in death.
People with breathing problems should consult
a physician before using this heater. Early signs
of carbon monoxide poisoning resemble the
flu. Symptoms of improper ventilation/carbon
monoxide poisoning are:
Headache • Dizziness • Nausea • Dry Mouth
Sore Throat • Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more affected by carbon monoxide
than others. These include: pregnant women, those
with heart or lung problems, anemia or those under
the influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED
ONLY FOR: The temporary heating of adequately
ventilated buildings or structures under
construction, alteration or repair! Provide at
least a three square foot (2,800 sq cm) opening
of outside air for every 100,000 Btu/Hr (29 kW)
heater rating. Refer to "Ventilation" on page 7 for
further instructions.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
SAFETY INFORMATION (CONT.)
RISK OF INDOOR
AIR POLLUTION!
CARBON
MONOXIDE
POISONING MAY
WARNING
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heater's fuel tank while the heater
is operating or still hot. This heater is EXTREMELY
HOT while in operation.
NEVER block air outlet (front).
WARNING
NEVER use duct work in front of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
80-OFR
Top
4 ft. (125 cm)
Sides
4 ft. (125 cm)
Front
8 ft. (250 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it
is plugged in, it can start at anytime in accordance
with the thermostat setting.
WARNING
TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING
AND COMBUSTIBLES AWAY FROM HEATER.
3
Kerosene Radiant Heater User's Manual
RISK OF ELECTRIC
SHOCK!
RISK OF BURNS,
FIRE AND
EXPLOSION!
125-OFR-A
6 ft. (185 cm)
6 ft. (185 cm)
8 ft. (250 cm)
CAUTION! HOT
WHILE IN OP-
ERATION. DO NOT

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Mh-125-ofr-a

Tabla de contenido