Wear Parts; Troubleshooting - Oase BioPress UVC 1000 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

- English -
Storage/Winterization
● Pull out and replace the UVC lamp (Section: Replacing the UVC lamp).
● Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are
to be expected.
● Drain and thoroughly clean the unit, check for damage.
● Remove, clean, dry and store all filters in a frost-free environment.
● Ensure that the storage place is inaccessible to children.
● Cover the filter container such that the ingress of rain water is excluded.
● Drain all hoses, pipes and connections.

Wear parts

The UVC lamp, the quartz glass and the filters are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.

Troubleshooting

Issue
Cause
The unit
Unit has been in operation only for
performance is
a short time
not satisfactory
Water extremely soiled
Excessive fish and animal
population
Foam filters soiled
Quartz glass tube soiled
UVC lamp capacity exhausted
UVC lamp
Power supply of the UVC not
display is not lit
connected
UVC lamp defective
Connection defective
UVC overheated
No water outlet
Pump power supply not connected
from the pond
Pond inlet blocked
inlet
Filter container/pump housing
clogged
Solution
The complete biological cleaning effect is only achieved after
several weeks
Remove algae and leaves from the pond, change the water
Guide value: approx. 2 ft (60 cm) fish length in 265 gal (1 m³)
pond water
Clean filters
Remove UVC and clean quartz glass
Replace the lamp after approx. 8,000 operating hours
Connect UVC power plug
Replace the UVC lamp
Check electrical connection
UVC automatically switches on when cooled down
Connect pump power supply
Clean pond inlet
Clean filter container/pump housing
10