To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove the burner caps.
3. Using a Phillips screwdriver, remove the burner base.
A .........................
A. Burner cap
B. Gas tube opening
C. Burner base screws
D. Burner base
4=
Apply masking tape to the end of a %2" (7.0 mm) nut driver to
help hold the Natural gas orifice spud in the nut driver while
changing it. Press nut driver down onto the Natural gas orifice
spud and remove by turning it counterclockwise
and lifting
out. Set the Natural gas orifice spud aside.
A. Natural gas orifice spud
Use the following chart for correct LP gas orifice spud for each
burner. Refer to the model/serial
rating plate behind the control
panel for proper sizing of LP gas orifice spuds for each burner
location.
LP Gas Orifice Spud Chart
Burner Rating
Color
Number
4,000 BTU
Blue
64L
9,100 BTU
Clear
91L
10,000 BTU
Green
97L
14,000 BTU
Red
114L
5. Replace the Natural gas orifice spud with the correct LP gas
orifice spud. See the "LP Gas Orifice Spud Chart."
6. Replace burner base and hand tighten the screws.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
9. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
10. Replace burner grates.
11. Complete installation. See "Make Gas Connection"
and
Electronic Ignition System" sections.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
1/4"to 1/2"long. The outer cone is not as distinct as the inner
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip
bracket to rear range foot.
Reconnect
the anti-tip bracket,
if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
B
A_
....................
C
A. Torange
B. Shutoff valve (closed position)
C. Gas supply line
To Convert Gas Pressure
Regulator
1. Locate gas pressure regulator at the rear of the range.
A. Gas pressure regulator
IMPORTANT:
Do not remove the gas pressure regulator.
14