GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
Explosion Hazard
Use a new CSA international approved
gas supply line.
install a shut-off valve,
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed
heating personnel,
authorized
gas company
personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion, or fire.
To Convert Gas Pressure
Regulator
1. Locate gas pressure regulator at the rear of the range.
2=
A. Gas pressure regulator
IMPORTANT:
Do not remove the gas pressure regulator.
Unscrew the hex-shaped
regulator cap from the regulator
and remove the regulator pin.
A
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip
bracket to rear range foot.
Reconnect
the anti-tip bracket,
if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children
and adults.
1. Turn manual shutoff valve to the closed position,
2. Unplug range or disconnect
power.
..............
B
A
'_
.............................
C
A. Torange
B. Shutoff valve (closed position)
C. Gas supply line
3=
B
A. Regulator pin
B. Regulator cap
Flip the regulator pin over and snap pin firmly into place.
A. Natural gas position
B. LP gas position
4. Screw the hex-shaped regulator cap securely back into
place. Do not overtighten.
To Convert
Oven Bake Burners
To Convert Lower Oven Bake Burner:
1. Remove oven racks from inside the oven cavity,
2. Remove oven door. See "Oven Door" section in the Use and
Care Guide for oven door removal instructions,