Formato De Salida 1 - SICK Master Data Analyzer Instrucciones De Uso

Tabla de contenido
10
DATOS TÉCNICOS
10.4.2

Formato de salida 1

Columna Campo
1
Start of text
(special character)
2
Object number
(ON)
Separator
3
Item identification
(BC)
Separator
4
Weight
(OWE)
Separator
5
Unit Weight
(OWU)
Separator
6
Scale error
(connection)
(Byte 1 of SEID)
Separator
7
Length
(OLE)
Separator
8
Width
(OWI)
Separator
9
Height
(OHE)
Separator
10
UnitVMS
(OUD)
Separator
11
VMS Status 1
(OMS1)
Separator
12
Cubic Volume
13
End of text
(special character)
Tab. 20: Descripción de la interfaz de datos: formato de salida 1
120
I NS T R U C C I O NES DE U S O | Master Data Analyzer
Bytes
Descripción
1
STX
4
Measurement
identification index
1
;
Variable Barcode content
of one barcode
1
;
9
Gross (brutto)
weight from scale
1
;
1
Units of weight
1
;
1
Scale is
connected/
disconnected
1
;
4
VMS measurement 0321
1
;
4
VMS measurement 0150
1
;
4
VMS measurement 0087
1
;
2
Units of MVS
measurements
1
;
4
0000
1
;
7
VMS measurement
LxWxH
1
ETX
Ejemplo
Indicación
0145
Internal index or external tray index (optional).
;
1JVGL0012345
May contain one barcode usually.
Also filtering functions to distinguish relevant
barcodes are available.
If no barcode could be read: No Read is sent
out.
;
000081212
Weight value is zeroed if the measurement
was not legal for trade/if there was an error.
;
g
;
1
First Byte of SEID:
0 for scale is connected.
1 for scale is not connected (e.g. not powered/
switched on).
;
Zeroed if measurement error.
;
Zeroed if measurement error.
;
Zeroed if measurement error.
;
mm
mm
;
0000 nor error
Hex. Format.
0001 item
Output will be suppressed in case of an error.
outside reading
field
;
cm3
Same as Display Output.
Terminator.
8025895-ZW99/V2-0/2019-08-
15|SICK
Sujeto a cambio sin previo aviso
Tabla de contenido
loading

Tabla de contenido