Maintenance - SATA jet 5000 B PHASER Instrucciones De Servicio

Ocultar thumbs Ver también para jet 5000 B PHASER:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 119
Operating Instructions SATAjet 5000 B RP/HVLP PHASER
• Check spray pattern after cleaning the nozzle set!
• Further tips concerning cleaning can be found at www.sata.com/TV.
9.

Maintenance

• Prior to maintenance, disconnect spray gun from the compressed air
circuit!
• Disassemble and install components very carefully! Exclusively use
included special tools!
9.1. Replacing the nozzle set
and [7-6]
Every SATA nozzle set consists of the paint needle [7-1], air cap ring [7-
2], air cap [7-3] and fluid tip [7-4] and is adjusted by hand to produce a
perfect spray pattern. Press old air cap out of the cap ring by hand [7-5].
Grease the paint needle [7-1] at the needle seal (approx. 3 cm before the
needle bushing, paint needle spring) and thread of the material flow con-
trol screw [1-11]. Therefore always replace the complete nozzle set. After
installation, adjust the material flow according to chapter 7.2.
9.2. Replace air distribution ring
[8-1], [8-2] [8-3], [7-6], [7-7] and [7-8]
• Remove air distribution ring with SATA extraction tool only.
• Do not apply force to avoid damage of sealing surfaces.
Notice!
Warning! Attention!
Attention!
[7-1], [7-2], [7-3], [7-4], [7-5]
steps: [7-1], [7-2], [7-3],
EN
111
Tabla de contenido

Solución de problemas

loading

Tabla de contenido