SATA jet 5000 B PHASER Instrucciones De Servicio página 113

Ocultar thumbs Ver también para jet 5000 B PHASER:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 119
Operating Instructions SATAjet 5000 B RP/HVLP PHASER
9.5. Repaling the sealing (air side)
• Disconnect spray gun from the compressed air circuit!
Steps: [9-1], [9-2], [10-1], [10-2], [10-3], [10-4] and [10-5]
Replacing the self-adjusting sealing [10-5] is required when air leaks
from under the trigger.
1. After dismantling, check the air piston rod [10-4]; clean it if necessary
or replace if damaged (e.g. scratched or bent), grease with SATA high
performance grease (Art. No. 48173) and mount in position, making
sure it is fitted in the right direction!
2. Also grease air micrometer shell, insert with air piston and tighten
locking screw using original SATA combination tool with max. 1 Nm.
After installation, please adjust material flow according to chapter 7.2.
• Check if locking screw has been firmly tightened! Air micrometer could
shoot out from the spray gun uncontrolled!
9.6. Replace CCS (ColorCode-System)
The CCS for the individual marking of the spray gun can be exchanged
according to [10-6].
9.7. Replace spindles of the round/flat fan control
steps: [11-1], [11-2], [11-3]
The spindle has to be replaced when air leaks from the fan control or
when the fan control does not work.
1. Removing the old spindle
Remove screw [11-1] (Torx T20)
Remove knob [11-2]
Unscrew spindle [11-3] with wrench (size 14)
Make sure that the spindle pick-up is free of material and paint resi-
dues, remove residues and clean with solvent, if necessary
2. Installation and position of new spindle
Screw in spindle [11-3]
Place the knob [11-2] on hexagonal of spindle
Warning!
Warning!
EN
113
Tabla de contenido

Solución de problemas

loading

Tabla de contenido