Technical Data; Performance Specifications - Graco 127642 Manual De Instrucciones

Ocultar thumbs Ver también para 127642:
Idiomas disponibles

Idiomas disponibles

F

TECHNICAL DATA

F1

PERFORMANCE SPECIFICATIONS

The performance diagram shows fl w rate as a function of back pressure.
Functioning
Point
28
A
(Maximum fl w rate)
32
27
B
(High fl w rate)
31
25
C
(Normal conditions)
29
D
0
(By pass)
NOTE
The curve refers to the following operating condi-
tions:
Fluid: DEF
Temperature: 20° C (68 °F)
Suction conditions: The pipe and the pump position
relative to the fluid level is such that a low pressure
of 0.3 bar (4 psi) is generated at the nominal flow
rate.
Under different suction conditions higher low
pressure values can be created that reduce the flow
rate compared to the same back pressure values. To
obtain the best performance, it is very important to
reduce loss of suction pressure as much as possible
by following these instructions:
• shorten the suction pipe as much as possible
• avoid useless elbows or throttling in the pipes
• keep the suction filter clean
• use a pipe with a diameter equal to, or greater
than, indicated (see Installation).
NOTE
By-pass pressure is 1.7 bar (24 psi)
NOTE
The wetted materials used in this device are :
stainless steel, plastic and rubber suitable for AdBlue.
M0307
Typical Delivery Configu ation
120
3.1
230
1.2
120
3.2
230
1.3
120
3.3
230
1.3
120
3.3
Delivery closed
230
1.3
Back pressure (bar)
EN
7
loading

Este manual también es adecuado para:

127645