Configuration
Control functions - DSW1
DIP switch
DSW1.1
DSW1.2
DSW1.3
Adjust current - DSW1.6 to DSW1.8
Information
Only a maximum value, which is smaller or equal to the operating current
according to the type plate, can be set with the DIP switches.
DIP switch
DSW1.6
DSW1.7
DSW1.8
DSW1.6
DSW1.7
DSW1.8
DSW1.6
DSW1.7
DSW1.8
DSW1.6
DSW1.7
DSW1.8
40
Function
External enable input X1 is used.
DSW1.1 ON: Charging enable with X1 closed
AND correct RFID authorization.
DSW1.1 OFF: Charging enable with X1 closed
OR correct RFID authorization.
For details, see
7.4 Enable input X1 (except
xChargeIn
A Series).
Switching of the function of the switch contact
output X2.
DSW1.2 ON: X2 as contactor monitoring
DSW1.2 OFF: X2 as charging status indicator
For details, see
7.5 Switch contact output X2
(except xChargeIn
A Series).
Enable UDP interface (SmartHome).
Only available for xChargeIn S Series and
M Series.
For details see "UDP Programmer's Guide".
Current
10 A
13 A
16 A
20 A
xChargeIn
Illustration
Illustration
Installation manual V1.01
© EATON
Tabla de contenido