Skil models SB18B-LI & SB18C-LI lithium ion battery packs are compatible with all existing Skil
18V tools that use the SB18A, SB18B and SB18C Ni-Cd batteries.
Only use the specified charger to charge your Li-Ion batteries. Do not charge
W RNING
Li-ion batteries with a Ni-Cd charger.
IMPORTANT CHARGING NOTES (LITHIUM-ION BATTERIES)
1. The charger was designed to fast charge
the battery only when the battery temperature
is between 32˚F (0˚C) and 113˚F (45˚C). If the
battery pack is too hot or too cold, the charger
will not fast charge the battery. (This may
happen if the battery pack is hot from heavy
use). When the battery temperature returns to
between 32˚F (0˚C) and 113˚F (45˚C), the
charger will automatically begin charging.
2. A substantial drop in operating time per
charge may mean that the battery pack is
nearing the end of its life and should be replaced.
3. Remember to unplug charger during storage
period.
4. If battery does not charge properly:
BATTERY CHARGE CONDITION INDICATOR LIGHTS (SB18B-LI BATTERY)
Your battery pack is equipped with charge
condition indicator lights (Fig. 9). The indicator
lights shows the charge condition of the
battery during operation.
To check battery charge condition, depress
and hold the button on the backside of the
battery pack.
* B TTERY
CH RGE
CONDITION
INDIC TOR
LIGHTS
Plug charger cord into your standard power
outlet, then insert battery pack into charger
(Fig. 10).
If the green indicator light is "ON",
the charger is plugged in but the
battery pack is not inserted, or the
battery pack is fully charged.

OPTIONAL ACCESSORY

FIG. 9
* BUTTON
CHARGING BATTERY PACK (SC118B-LI CHARGER)
a. Check for voltage at outlet by plugging in
some other electrical device.
b. Check to see if outlet is connected to a
light switch which turns power "off" when lights
are turned off.
c. Check battery pack terminals for dirt.
Clean with cotton swab and alcohol if
necessary.
d. If you still do not get proper charging,
take or send tool, battery pack and charger to
your local Skil Service Center. See "Tools,
Electric" in the Yellow Pages for names and
addresses.
Note: Use of chargers or battery packs not
sold by Skil will void the warranty.
LED
Continuous lighting 3 x blue
Continuous lighting 2 x blue
Continuous lighting 1 x blue
Slow flashing 1x blue
LED
Error Message
Alternating
Battery temperature is not
left middle
within normal operating
right 1
temperature range of
x blue
0°C (32°F) to 45°C (113°F),
or battery current is over
the normal operating range.
If the green indicator light is
"BLINKING", the battery pack is
being
charging will automatically stop when the
battery pack is fully charged.
-13-
Capacity
66% - 100%
34 - 65%
11 - 33%
0% - 10%
fast-charged.