Danger!
When using the equipment, a few safety pre-
cautions must be observed to avoid injuries and
damage. Please read the complete operating
instructions and safety regulations with due care.
Keep this manual in a safe place, so that the in-
formation is available at all times. If you give the
equipment to any other person, hand over these
operating instructions and safety regulations as
well. We cannot accept any liability for damage
or accidents which arise due to a failure to follow
these instructions and the safety instructions.
Explanation of the warning signs on the
machine (Fig. 8)
1. Danger! Read the operating instructions.
2. Warning! Hot parts. Keep your distance.
3. Danger! Switch off the engine before refueling.
4. Danger! Never operate in non-ventilated rooms.
1. Safety regulations
Danger!
Read all safety regulations and instructions.
Any errors made in following the safety regula-
tions and instructions may result in an electric
shock, fi re and/or serious injury.
Keep all safety regulations and instructions
in a safe place for future use.
•
No changes may be made to the generator.
•
Only original parts may be used for mainte-
nance and accessories.
•
Important: Danger of poisoning, do not inhale
•
emissions.
•
Children are to be kept away from the gene-
rator.
•
Important: Risk of burns. Do not touch the
exhaust system or drive unit.
•
Wear suitable ear protection when in the vici-
nity of the equipment.
•
Important: Petrol and petrol fumes are highly
combustible or explosive.
•
Never operate the generator in non-ventilated
rooms or in easyly inflammable adjacency.
When operating the generator in rooms with
good ventilation, the exhaust gases must
be channeled directly outdoors through an
exhaust hose. Important: Toxic exhaust gases
can escape despite the exhaust hose. Due to
the fire hazard, never direct the exhaust hose
towards inflammable materials.
•
Risk of explosion: Never operate the genera-
Anl_HSE_720_SPK7.indb 13
Anl_HSE_720_SPK7.indb 13
GB
tor in rooms with combustible materials.
•
The speed preset by the manufacturer is not
allowed to be changed. The generator or
connected equipment may be damaged.
•
Secure the generator against shifting and
toppling during transport.
•
Place the generator at least 1m away from
buildings and the equipment connected to it.
•
Place the generator in a secure, level positi-
on. Do not turn, tip or change the generator's
position while it is working.
•
Always switch off the engine when trans-
porting and refueling the generator.
•
Make sure that when you refuel the generator
no fuel is spilt on the engine or exhaust pipe.
•
Never operate the generator in rain or snow.
•
Never touch the generator with wet hands.
•
Guard against electric danger. When working
outdoors, use only extension cables that are
approved for outdoor use and which are
marked accordingly (H07RN..).
•
The overall length of the extension cables
used may not exceed 50 m for 1.5 mm
100 m for 2.5 m
.
2
•
No changes may be made to the settings of
the motor or generator.
•
Repairs and adjustment work may only be
carried out by authorized trained personnel.
•
Do not refuel or empty the tank near open
lights, fire or sparks. Do not smoke!
•
Do not touch any mechanically driven or hot
parts. Do not remove the safety guards.
•
Do not expose the tools to damp or dust.
Permissible ambient temperature – 10 to +
40 °C, max. altitude above sea level 1000 m,
relative humidity: 90 % (non-condensing)
•
The generator is driven by a combustion en-
gine, which produces heat in the area of the
exhaust (on the opposite side of the sockets)
and the exhaust outlet. You should therefore
keep clear of these surfaces because of risk
of skin burns.
•
The values quoted in the technical data for
sound power level (LWA) and sound pressure
level (LWM) are emission values and not ne-
cessarily reliable workplace values. As there
is a correlation between emission and immis-
sion levels, the values are not a reliable basis
for deciding on any additional precautions
which may be needed. Factors infl uencing
the actual user immission level include the
properties of the work area, other sound sour-
ces etc., the number of machines and other
processes in the vicinity, as well as the time
span in which the operator is subjected to the
- 13 -
and
2
27.09.2016 14:30:41
27.09.2016 14:30:41