1.
Plug power cable in.
2.
Check to see that the power indica-
tor (20) is illuminated.
3.
Open discharge line.
Press the reset button (22). The
4.
pump will start running.
If there is no water pumped after
approx. 10 seconds the Hydromat
will turn off.Then press and hold the
(22)
reset
button
emerges.
If no water emerges after approx. 3
minutes, check the suction line.

7. Care and Maintenance

A
Danger!
Prior to all servicing:
1.
Turn OFF.
2.
Unplug.
3.
Ensure that pressure is relieved
from the pump and connected
accessories.
Service and repair work other than
described here must be left to quali-
fied specialists.
7.1

Danger of Ffreezing

A
Caution!
Frost damages the pump and
accessories, as both always contain
water!
When there is danger of freezing,
dismount the pump and accessories
and store at a frost-free location
(see below).
7.2
Pump Dismounting and
Storing
1.
Turn pump OFF and unplug.
2.
Open pressure line (open tap or
spray nozzle) and drain water com-
pletely.
3.
Drain pump completely; to do so
remove the drain plug from the
pump
4.
Disconnect suction and pressure
lines from the pump.
5.
Store pump in a frost-free location
(at least 5 °C).

8. Trouble Shooting

Danger!
A
Prior to all servicing:
1.
Turn OFF.
2.
Unplug.
3.
Ensure that pressure is relieved
from the pump and connected
accessories.
8.1

Locating the Fault

Pump does not run:
 Pump not turned ON.
• Start pump
switch.
 Hydromat has cut out.
• Press the reset button. 
If no water is pumped after
approx. 10 seconds, press and
hold reset button until Water
emerges.
 No mains voltage.
• Check cables, plug, outlet and
until
water
mains fuse.
 Mains voltage too low.
• Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
 Motor overheated, motor protection
relay tripped.
• After cooling off the pump will
start again.
• Ensure sufficient ventilation, keep
vent slots clear.
• Observe max. temperature of the
pumped medium.
 Motor hums but does not start.
• With the motor turned OFF, put
screwdriver or similar through the
fan cover's ventilation slots and
turn the fan.
 Pump blocked or out of order.
• Disassemble pump and clean.
• Clean diffusor, replace if neces-
sary.
• Clean impeller, replace if neces-
sary.
Pump does not prime correctly or
runs very noisily:
 Lack of water.
• Ensure there is a sufficient water
supply.
 Suction line leaky.
• Seal suction line, tighten screw
fittings.
 Suction head too high.
• Observe max. suction head.
• Install check valve, fill suction line
with water.
 Suction strainer (optional acces-
sory) blocked.
• Clean, replace if necessary.
 Check valve (optional accessory)
blocked.
• Clean, replace if necessary.
 Water leaks between motor and
pump, Duocone seal worn.
• Replace Duocone seal.
 Pump blocked or out of order.
• see above.
Pressure too low:
 Suction line leaky or too much suc-
tion head.
• see above.
 Pump blocked or out of order.
at the
ON/OFF

9. Repairs

A
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorized service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.

10. Environmental Protection

The packaging material of the pump is
100 % recyclable.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.

11. Available Accessories

For this pump the following accessories
are available from your dealer.
3
are shown at the end of this manual.
A
B
C
D
E
F
G
ENGLISH
• see above.
Danger!
Repairs to electric tools must
Note: 
Illustrations and stock numbers
Pump Installation Package, 
(MSS 310 – HWA/P), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
Pump Installation Package, 
(MSS 380 – HWW), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
Pump Installation Package, 
(MSS 200 – HWW/P), complete
with double nipple, check valve, fil-
ter short, washable filter cartridge,
spiral hose assembly 1 m, thread
sealing tape.
Pump Installation Package, 
(MSS 1000 – HWA), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
Filter (for garden pumps), 
1" connection, short, 
c/w washable synthetic material fil-
ter cartridge.
Filter (for domestic water systems), 
1" connection, short, 
c/w washable synthetic material fil-
ter cartridge.
Spiral Suction Hose 1" (standard)
1) 4 m, c/w quick release screw fit-
ting and strainer with foot valve;