Intake Valve 3/4", Cold Water; Accessory Module - Miele MF01 10–20 Instrucciones De Montaje

Tabla de contenido
Produktgruppe 512
45 von 48
Note
This installation kit for PW 6107, PW 6137 , PW 6167 and PW 6207 also contains:
2 M4x12.5 hex screws
1 intake valve, 3/4", cold water
1 sticker
1 hose
2 hose clamps, 8-16 mm
1 screw terminal, 4-pin, ecru
1 screw terminal, 4-pin, red
1 screw terminal, 6-pin, blue
1 screw terminal, 7-pin, green
1 terminal block, 1X3-4, orange
1 terminal block, 2X3-4, gray
1 terminal block, 3X3-4, blue
1 terminal block, 4X3-4, green/yellow
1 flat plug, 4-pin (dispensing pump ground)

1 accessory module

1 PW 6107 PW 6207 module 1 wiring diagram, mat. no. 09021410
These installation instructions, mat. no. 09081900.
List of illustrations:
Fig. 1, EZL 235 electronic installation
Fig. 2, Installing the intake valve on the connection strip
Fig. 3, EZL 235 wiring, module 1, liquid dispensing 1-6
Fig. 4, Installing the cable guide on the connection strip
Disconnect the machine from the electrical supply and gas supply (if applicable) and ensure that power cannot be switched on again
in error.
Remove the left and right screws from the machine lid.
Pull the lid slightly forward, push it back and unhook it from the connection strip.
Remove the lid.
Note
If wiring harness ELP 235 ST17 (external dispensing connection) is installed, it should be removed; see Fig. 3, Pos. 1.
Install the EZL 235 electronic with the 4 spacers in the pre-existing holes on the side of the module holder; see Fig. 1, Pos. 1, Pos. 2.
Install the terminal strips in the pre-existing holes on the module holder; see Fig. 1, Pos. 3.
Note
Terminal strip allocation, see Fig. 3.
Terminal block 1X3-4, orange
Terminal block 2X3-4, gray
Terminal block 3X3-4, blue
Terminal block 4X3-4, green/yellow
Remove the cover for liquid dispensing from the machine rear panel.
Knock out the pre-punched hole for the 3/4" intake valve on the rear panel; see Fig. 2, Pos. 1
Install the 3/4" cold-water intake valve using the 2 M4x12.5 screws; see Fig. 2, Pos. 1.
Install the hose with hose clamps. Pay attention to the hose position on the mixer box and the hose clamps' screw orientation;
see Fig. 2.
Attach the cold water sticker to the outside, under the 3/4" cold-water intake valve; see Fig. 2, Pos. 2
Modify the existing connections:
Disconnect the plug from ELP 235
24.01.2012
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
ST14 and connect it to EZL 235
Umbau- und Montageanweisung
ST9 (module 1, liquid dispensing 1-6); see Fig. 3, Pos. 2.
M.-Nr. 09081900