SYMPTOM
POSSIBLE CAUSE
Lights will not come
1. Light switch is turned off.
on.
2. F l o o d l i g h t i s l o o s e o r
3. Fuse is blown or circuit breaker
4. Daylight turn-off is in effect (re-
5. Incorrect circuit wiring, if this is a
6. Re-aim the sensor to cover de-
Lights come on
1. Light control may be installed in
in daylight.
2. L i g h t control i s i n T e s t .
Lights come on
1. Light control may be sensing
for no apparent
reason.
2. Sensitivity is set too high. (Reduce
Please call 1-800-858-8501 (English speaking only) for assistance before returning
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com.
If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 8:00 AM to 5:00 PM CST
(M-F). You may also write* to:
HeathCo LLC, P.O. Box 90045
Bowling Green, KY 42102-9045
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur-
chase, and Place of Purchase.
Please keep your dated sales receipt, it is required for all warranty requests.

TROUBLESHOOTING GUIDE

burned out.
is turned off.
check after dark).
new installation.
sired area.
a relatively dark location.
(Set control switch to an
ON-TIME position).
small animals or automobile traf-
fic (re-aim sensor).
sensitivity.)

TECHNICAL SERVICE

product to store.
No Service Parts Available for this Product
SYMPTOM
POSSIBLE CAUSE
Lights stay on
1. A flood lamp is positioned too close to
continuously.
the sensor or pointed at nearby objects
that cause heat to trigger the sensor.
(Reposition the lamp away from the
sensor or nearby objects).
2. Light control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective sur-
face. (Reposition sensor).
3. Light control is in Manual Mode. (Switch
to Auto.)
Lights flash on
1. Heat or light from the lamps may be
and off.
turning the light control on and off.
(Reposition the lamps away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-
tion sensor).
3. Light control is in the Test mode and
warming up. (Flashing is normal under
these conditions).
4. Light may be leaking through the
floodlamp reflectors. (Replace the
lamps with new high quality PAR 38
lamps).
4