INSTALLATION
For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground. NOTE: If fixture is mounted
higher than 8 ft. (2.4 m), aiming the sensor down will reduce
coverage distance.
❒ Drill the holes needed to mount the
backplate to the junction box.
Eave Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Rotate the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
❒ Remove the existing light fixture.
❒ Route the light control's wires through the large
❒ Connect the junction box wires to the light control
White to White
Wall Mount
❒ Align the light control cover plate and the junction
❒ If not installed on a weatherproof box or if an adaptor
Controls
Lock nuts
❒ Adjust the lamp holders by loosening the lock nuts
2
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
gasket hole.
wires. Twist together and secure with a wire
connector.
Black to Black
Mount the Light Control
box holes. Secure with the mounting screws.
plate (not included) was used, caulk the wall plate
and mounting surface with silicone.
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the flood-
lamps, do not overtighten.
Gasket
Avoid water damage and
electrical shock - keep lamp
holders below horizontal.
Keep lamps at
least 1" (25 mm)
from the sensor.
204020-02